QWhat Protection Materials Used by meralco to High Tension Cable (Wire)?AProtection material of high tension wire which greater than 11kV is XLPE insulation, and outer sheath such as plastic, rubber, steel wire armor(SWA), steel tape armor(STA), aluminum wire armor(AWA), aluminium tape armor(ATA), chain armor, aluminum wrinkles sheath etc.
-
QHow to see H07RN-F Cable Size?AYou can get H07RN-F cable size by checking the printing word on cable or measuring the single wire of the conductor.
-
QWhat Industry Uses Flexible Wires and CablesAFlexible wires and cables are widely used in factory machinery mining machinery and mobile equipment and so on.
-
QWhat industry uses control cable?AControl cables are used in factory equipment, power plants, switch gear, and where there is control equipment.
-
QWhat happen to the Electric wire when bent?AIf conventional cable bend radius is less than the minimum radius the cable insulation can't reach standard thickness because of convex curvature of cable end excessive bending, thus affecting the insulation effect, lead to cable breakdown, or even cause a fire or other accidents. If the electric wire is armored cable, the problem is more serious, because bending over with armor will pierce the outer sheath and inner insulation, leading to accidents. When you install the bridge, the bridge should be done to meet the bending radius. Do not install 90 degree; you can use two 45-degree angle cut to meet the 90 elbow.
-
QHow to lay underground cable?AUnderground cable laying technical requirements 1. Identify circuit trend: identify the circuit trend according to electricity distribution requirements and design drawings; 2. Burial depth should generally be in deep underground 0.7m, when it is close proximity with other channels and other cable should be buried in the depths of 1m; 3. The bottom of underground cable ditch must be flat, or spread a thick 100mm of fine soil in the ditch, and the installation of signs on the ground; 4. When the underground cables lay cross the road should wear sleeve protection; 5. Metallic sheath ends of armored cables and lead sheathed cables must be grounded. 6. There are a variety of cable lines laying method, commonly used methods are buried laying, cable trench laying, tunnel laying pipe laying and brightly laying indoor and outdoor. Underground cable circuit laying method 1. Firstly, dig trenches. underground cable laying need to dig a trench depth of about 0. 8m on the ground, trench width is 0. 6m. After the formation of the ditch covered with 100mm thick fine sand as underground cables cushion. 2. Cable laying usually divided into two kinds manual laying and mechanical traction. Manual laying is used for laying cables with small size, two people stood on both sides of the cable channel, carrying cable tray forward slowly along the laying direction, gradually release the cable reel, fall into the trench; mechanical traction is used for any size cables, every two meters to place a wheel in cable ditch, located pay-off rack at one end of the cable channel, placed winch or windlass at the other end, 8 to 10 meters i minute to pull the cable out, falls on the wheel, then withdraw the wheel, the cable loosely deposited in the ditch, to extend and retract. On the cable and then covered with 100mm thick soft soil or fine sand, covered with brick or concrete cover, covering both sides of the cable diameter should exceed the width 5omm finally filling in the cable trench backfill above the ground to 150- 200mm, and at both ends of the cable line, intermediate and corner joints erected Flag piles. 3. Finished the intermediate connector and terminal head of cable, cable construction is going to complete, before delivery, it must be do related tests.